12V 60Ah-55Ah AGM Deep Cycle Battery

Technology: Flat Plate AGM
Terminals: Copper
Rated Capacity: 10 Hour Discharge at 25C
Float Design Life: 7-10 Years @ 20C
Cyce Design Life: 200 Cycles @ 100%, 400 Cycles @ 50%, 900 Cycles @ 30%

BAT412550080

Freephone Tel: 0800 091 4148 
International Sales: +44 (0)141 892 2840 
sales@thepowerstore.co.uk 
Home | About Us | Contact Us | Checkout | Add to Favourites Electronic Components | Power Conversion | Cable Assemblies
Part No: 
QuickCode:4F1
12V 60Ah-55Ah AGM Deep Cycle Battery
recommend to a friend
Victron Energy
Ask for more information
technical spec
 
 RRP: £140.00
Our Price:
£122.00
VAT @ 17.5%:
£21.35
Total:
£143.35
 
Qty
 
Seen it cheaper?
Additional  Information
VRLA technology
 
VRLA stands for Valve Regulated Lead Acid, which means the batteries are sealed. Gas will escape through the safety valves only in case of overcharging or cell failure. VRLA batteries have exceptional leak resistance, and can be used in any position. VRLA batteries are maintenance free for life.
 
Sealed (VRLA) AGM batteries
 
AGM stands for Absorbent Glass Mat. In these batteries the electrolyte is absorbed into a glass-fibre mat between the plates by capillary action. As explained in our book ‘Energy Unlimited’, AGM batteries are more suitable for short-time delivery of very high currents (engine starting) than gel batteries.
 
Sealed (VRLA) Gel batteries
 
Here the electrolyte is immobilized as gel. Gel batteries in general have a longer service life and better cycle capacity than AGM batteries. 
 
Low Self-discharge
 
Because of the use of lead calcium grids and high purity materials, Victron VRLA batteries can be stored during long periods of time without recharge. The rate of self-discharge is less than 2% per month at 20°C. The self discharge doubles for every increase in temperature with 10°C. Victron VRLA batteries can therefore be stored during up to a year without recharging, if kept under cool conditions.
 
Exceptional Deep Discharge Recovery
 
Victron VRLA batteries have exceptional discharge recovery, even after deep or prolonged discharge. It should however be stressed that repetitive deep discharge and prolonged discharge have a very negative influence on the service life of all lead acid batteries, Victron batteries are no exception.
 
Battery discharging characteristics
 
The rated capacity of Victron batteries refers to a 10 hour discharge, in other words: a discharge current of 0,1 C. The effective capacity decreases with increasing discharge current (see table). Please note that the capacity reduction will be even faster in case of a constant power load, such as an inverter.
Our AGM deep cycle batteries have excellent high current performance and are therefore recommended for high current applications such as engine starting. Due to their construction, Gel batteries have a lower effective capacity at high discharge currents. On the other hand, Gel batteries have a longer service life, both under float and cycling conditions
 
Please see the datasheet for the full Battery Specification

Search

QuickCode

Power Manufacturers

Feller Power Cables


Electronic Components

Click for full list

Trade Enquiries

For volume or trade enquiries please call 0800 091 4148

Fast Delivery


Most orders are sent out by DPD for delivery on the next working day (subject to stock availability and orders placed before 16:00).

Valid HTML 4.01 Transitional About Us | Site Map | Privacy Policy | Terms and Conditions |Contact Us | ©2007 CCL Components